Free on your own file
One analyte from your file: the bias at each of your decision lines and how many results crossed each line. No account, nothing to install.
Change check
For the lab QA manager or quality lead planning an analyser, reagent or method change: see which of your method-comparison results cross your decision lines, in your browser, without uploading your file. Free on your own file (one analyte) and on the public example. The full change report is US$490.
Before you pay
One analyte from your file: the bias at each of your decision lines and how many results crossed each line. No account, nothing to install.
The whole change report, every panel the price buys, on 1,428 paired full blood count results (204 samples, 7 analytes) from an open-access deposit. See exactly what you would get before you pay.
Every analyte in your file, each crossing set beside what repeat testing alone would cause, the old-by-new category matrix, the crossed-sample list and a printable report. Full refund within 14 days of payment, for any reason. Invoice or purchase order on request.
The figures in your browser are the figures of our reference program: on 14 public comparison data sets, 2,165 of 2,165 figures agreed. How they are computed: method.
Run it
Drop your paired-results file here
A CSV with one row per sample and analyte: pair_id, analyte, unit, value_old, value_new, old_system, new_system. Comma, semicolon, tab or bar separated; decimal commas are read. Optional: replicate_timing, set to different_day only if your duplicate samples were run on different days; if the column is missing, duplicates are reported as within-run and not used as repeat-test noise.
Or a Validation Manager comparison table: the test run results table of a comparison study (Sample, candidate, comparative, Difference), saved as text or CSV. Choose several at once for several analytes. Layout from published screenshots; tell us if your export differs.
Validation Manager is a product of Ascentry. NakedSignal is not affiliated with Ascentry.
Your file stays on this computer. This page reads it in your browser and never uploads it. The only things this page can send are a payment check (a payment reference, nothing about your file), a cookieless count of what was done here (for example “a file was opened”, never the file, its name or a result) and, if you choose to, the summary shown under “Contribute”.
The example is 1,428 paired full blood count results (204 samples, 7 analytes) from an open-access deposit (PMC12956494 (opens in a new tab), CC BY 4.0), with the systems shown under generic names. On the example the full change report is shown free. Download the CSV template.
US$490 per change report
Every analyte in your file, the crossing counts set beside repeat testing, the category matrix, the crossed-sample list and a printable report. Paid by card through Stripe. Terms of sale.
Stripe takes the payment for CareerLoop Inc., the company behind NakedSignal; that name appears on your card statement.
Full refund within 14 days of payment, for any reason.
Payment opens in a new tab. Keep this tab open: when payment completes, the report unlocks here too, with your file still loaded.
Need an invoice or a purchase order instead of a card? Ask for an invoice.
Running method comparisons for client laboratories? Buy one change report per study, at the same price, and ask for the invoice in your client’s name if that suits them.
01Intended use
The NakedSignal change check is laboratory-management software. It is intended for use by laboratory scientists to describe, for a population of paired results, how a change of analyser, reagent or method moved results across the decision lines the laboratory chose, and to plan the laboratory’s own verification, re-testing capacity and communication with clinicians.
It is not intended to diagnose, monitor or treat any person, to change, correct or re-report any patient result, or for any time-critical decision. The list of individual samples is for review by the laboratory under its own procedures and is not a recommendation about any patient.
It is for a laboratory professional responsible for method verification and method change: a clinical or biomedical scientist, laboratory director or quality manager who knows method comparison and the laboratory’s own decision limits. It is not intended for clinicians or patients.
Warnings
02Method
Per analyte and pair of systems: the comparison line is a Passing-Bablok regression of new on old; the average difference and limits of agreement are Bland-Altman; the bias at a decision line is the comparison line’s value there minus the line. A result crosses a line when its old and new values fall on different sides of it. “Expected from repeat testing” models a repeat on one system as normal with the repeat-test CV, so the crossings a change causes can be set beside those that no change at all would cause. Groups with fewer than twenty usable pairs are not computed.
The report counts how many results changed category and compares that with what repeat testing alone would do. It is a measure of patient impact, not a sensitive test: in our simulation on one public creatinine data set, on 20 to 60 samples it usually did not flag a shift of one or two times the assay's CV, and other analytes and patient groups will differ. Treat a quiet count on a small set as no evidence either way.
The browser engine gives the same figures as the reference program behind our full site report: on 14 public comparison data sets (34 analyte groups), 2,165 of 2,165 figures agreed. Not computed in the browser: bootstrap intervals and the re-test band, which are part of the full site report (see the sample report).
Default decision lines, assumed precisions and acceptance limits are common published values, each labelled with its source; replace them with your laboratory’s own. The assumed precisions come in two sets: one for comparisons between laboratory analysers, from published laboratory precision near the decision lines where we have it, and one set deliberately high for comparisons with a point-of-care device. More on the method: how it works.
The optional change record offers LOINC codes, with their names, from LOINC version 2.82, to identify the test; it is not advice on how to code one.
This material contains content from LOINC (http://loinc.org). LOINC is copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc.
03Your data
The file is opened by this page in your browser and computed there. It is not uploaded to us or to anyone else, and the page keeps no copy once you close it. Use your own pair IDs, never a patient identifier or name.
The page makes two kinds of request about your check, both optional: a payment check, which sends only the payment reference Stripe returns, and, if you choose to contribute and press send, the derived summary you see before sending, to the Analyser-Change Registry. Like every page on this site it also sends cookieless page counts, and here a count of what was done (the example tried, a file opened, the payment or invoice link pressed), never the file, its name or a result: see the privacy notice. Terms of sale and the refund rule: change check terms.